• sales@intesalogic.com
  • Mon - Sat 8:30am - 6:00pm

สอบถามรายละเอียด

086-377-4532

Specification

B1L

IR Resolution

160 x 120 (19 200 pixels)

NETD

< 40 mK (@25°C), F#=1.0

FOV (Field of View)

32.9° × 44.4°

Image Frequency

25 Hz

Wi-Fi

802.11 b/g/n (2.4GHz)

Digital Resolution

N/A

Focus

Fixed

IFOV (Spatial Resolution)

4.85 mrad

Display

240 × 320 Resolution, 3.2’’ LCD Screen

Image Modes

N/A

Object Temperature Range

-20 °C to 550 °C (-4 °F to 1022 °F)

Accuracy

Max (±2°C/3.6°F, ±2%), for ambient temperature 15°C to 35°C (59°F to 95°F) and object temperature above 0°C (32°F)

Battery Operating Time

8 Hours Continuous Running

Protection Level

IP54

B2L

IR Resolution

256 x 192 (49 152 pixels)

NETD

< 40 mK (@25°C), F#=1.0

FOV (Field of View)

37.2° × 50.0°

Image Frequency

25 Hz

Wi-Fi

802.11 b/g/n (2.4GHz)

Digital Resolution

N/A

Focus

Fixed

IFOV (Spatial Resolution)

3.3 mrad

Display

240 × 320 Resolution, 3.2’’ LCD Screen

Image Modes

Thermal/Optical/Fusion/PIP

Object Temperature Range

-20 °C to 550 °C (-4 °F to 1022 °F)

Accuracy

Max (±2°C/3.6°F, ±2%), for ambient temperature 15°C to 35°C (59°F to 95°F) and object temperature above 0°C (32°F)

Battery Operating Time

6 Hours Continuous Running

Protection Level

IP54

B10

IR Resolution

256 x 192 (49 152 pixels)

NETD

< 40 mK (@25°C), F#=1.0

FOV (Field of View)

37.2° × 50.0°

Image Frequency

25 Hz

Wi-Fi

No

Digital Resolution

1600 × 1200 (2 MP)

Focus

Fixed

IFOV (Spatial Resolution)

3.3 mrad

Display

240 × 320 Resolution, 3.2’’ LCD Screen

Image Modes

Thermal/Optical/Fusion/PIP

Object Temperature Range

-20 °C to 550 °C (-4 °F to 1022 °F)

Accuracy

Max (±2°C/3.6°F, ±2%), for ambient temperature 15°C to 35°C (59°F to 95°F) and object temperature above 0°C (32°F)

Battery Operating Time

6 Hours Continuous Running

Protection Level

IP54

B20

IR Resolution

256 x 192 (49 152 pixels)

NETD

< 40 mK (@25°C), F#=1.0

FOV (Field of View)

37.2° × 50.0°

Image Frequency

25 Hz

Wi-Fi

802.11 b/g/n (2.4GHz)

Digital Resolution

1600 × 1200 (2 MP)

Focus

Fixed

IFOV (Spatial Resolution)

3.3 mrad

Display

240 × 320 Resolution, 3.2’’ LCD Screen

Image Modes

Thermal/Optical/Fusion/PIP

Object Temperature Range

-20 °C to 550 °C (-4 °F to 1022 °F)

Accuracy

Max (±2°C/3.6°F, ±2%), for ambient temperature 15°C to 35°C (59°F to 95°F) and object temperature above 0°C (32°F)

Battery Operating Time

6 Hours Continuous Running

Protection Level

IP54